AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dobbin, K
Right arrow Articles by Chulay, M
Right arrow Search for Related Content
PubMed
Right arrow Articles by Dobbin, K
Right arrow Articles by Chulay, M
American Journal of Critical Care, Vol 1, Issue 2, 61-69
Copyright © 1992 by American Association of Critical Care Nurses


Articles

Pulmonary artery pressure measurement in patients with elevated pressures: effect of backrest elevation and method of measurement

K Dobbin, S Wallace, J Ahlberg, and M Chulay .

OBJECTIVE: To determine whether pulmonary artery pressure measurement is accurate if the head of the bed is elevated; to compare the end-expiratory graphic recording and digital monitor methods for pulmonary artery pressure measurement; to determine whether either mean arterial pressure or mixed venous oxygen saturation changes during backrest elevation. DESIGN: Nonrandomized clinical trial. SETTING: A six-bed cardiac surgical intensive care unit of a 540-bed federal facility. POPULATION: Twenty-five postoperative cardiac surgical patients with elevated pulmonary artery pressures (systolic higher than 35 mm Hg). INTERVENTIONS: In supine patients pulmonary artery pressures were measured at each of the following backrest elevations: 0, 20, 30, 45 and again at 0 degrees. Measurements were obtained once during mechanical ventilation and once during normal breathing after extubation. MAIN OUTCOME MEASURES: End-expiratory graphic recording of pulmonary artery pressures; digital monitor values of pulmonary artery pressures; mean arterial pressure; and mixed venous oxygen saturation. RESULTS: No statistical difference was found in pulmonary artery pressures measured at each of the backrest elevations during mechanical ventilation or normal breathing after extubation. Pulmonary artery diastolic and pulmonary capillary wedge pressures obtained with the digital monitor method were significantly lower than the end expiratory graphic recording method during normal breathing after extubation but not during mechanical ventilation. No changes in mean arterial pressure or mixed venous oxygen saturation occurred during backrest elevation. CONCLUSIONS: These results show that pulmonary artery pressures can be measured accurately with the head of the bed in an elevated position. The data indicate that obtaining pulmonary artery pressure measurements from the digital display of the bedside monitor is accurate when respiratory wave form fluctuations are minimal but may lead to inaccurate values with prominent respiratory fluctuations. Further research is needed to validate this finding in different patient populations and with other models of monitoring equipment.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association of Critical-Care Nurses.