AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Konopad, E
Right arrow Articles by Shustack, A
Right arrow Search for Related Content
PubMed
Right arrow Articles by Konopad, E
Right arrow Articles by Shustack, A
American Journal of Critical Care, Vol 1, Issue 3, 94-101
Copyright © 1992 by American Association of Critical Care Nurses


Articles

Comparison of PT and aPTT values drawn by venipuncture and arterial line using three discard volumes

E Konopad, M Grace, R Johnston, T Noseworthy, and A Shustack .

BACKGROUND: Blood samples obtained through heparinized arterial catheters are used routinely for a variety of laboratory tests. Accuracy of coagulation studies performed from samples obtained in this fashion continues to be questioned, particularly in regard to the minimum discard volume necessary to clear the catheter of heparinized solution. OBJECTIVE: To examine differences between prothrombin time and activated partial thromboplastin time values obtained from blood drawn by venipuncture and from an indwelling intra-arterial line using three discard volumes. METHODS: Prothrombin time and activated partial thromboplastin time samples were drawn by venipuncture from 41 critically ill adult patients. Simultaneously, three consecutive blood samples of 2.3 mL were drawn from the arterial line after an initial discard volume of 3 mL (discard volumes of 3.0, 5.3 and 7.6 mL). RESULTS: Significant differences were found between arterial and venous prothrombin time values for the 3-mL discard volume group, as well as between arterial and venous activated partial thromboplastin time values for all three discard volume groups (paired t-test, Bonferroni correction). CONCLUSION: We recommend that when drawing prothrombin time and activated partial thromboplastin time samples from an arterial line, a 5.3-mL discard volume be used.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1992 by the American Association of Critical-Care Nurses.