AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Critical Care. 2002;11: 141-149
Copyright © 2002 by the American Association of Critical-Care Nurses.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sole, M. L.
Right arrow Articles by Ludy, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sole, M. L.
Right arrow Articles by Ludy, J. E.

Bacterial Growth in Secretions and on Suctioning Equipment of Orally Intubated Patients: A Pilot Study

By Mary Lou Sole, RN, PhD, CCRN, F. Elizabeth Poalillo, RN, MSN, CCRN, Jacqueline F. Byers, RN, PhD, CNAA and Jeffery E. Ludy, EdD, RRT. From School of Nursing (MLS, FEP, JFB) and Cardiopulmonary Sciences (JEL), University of Central Florida, Orlando, Fla.

Background Contamination of equipment, colonization of the oropharynx, and microaspiration of secretions are causative factors for ventilator-associated pneumonia. Suctioning and airway management practices may influence the development of ventilator-associated pneumonia.

Objectives To identify pathogens associated with ventilator-associated pneumonia in oral and endotracheal aspirates and to evaluate bacterial growth on oral and endotracheal suctioning equipment.

Methods Specimens were collected from 20 subjects who were orally intubated for at least 24 hours and required mechanical ventilation. At baseline, oral and sputum specimens were obtained for culturing, and suctioning equipment was changed. Specimens from the mouth, sputum, and equipment for culturing were obtained at 24 hours (n = 18) and 48 hours (n = 10).

Results After 24 hours, all subjects had potential pathogens in the mouth, and 67% had sputum cultures positive for pathogens. Suctioning devices were colonized with many of the same pathogens that were present in the mouth. Nearly all (94%) of tonsil suction devices were colonized within 24 hours. Most potential pathogens were gram-positive bacteria. Gram-negative bacteria and antibiotic-resistant organisms were also present in several samples.

Conclusions The presence of pathogens in oral and sputum specimens in most patients supports the notion that microaspiration of secretions occurs. Colonization is a risk factor for ventilator-associated pneumonia. The equipment used for oral and endotracheal suctioning becomes colonized with potential pathogens within 24 hours. It is not known if reusable oral suction equipment contributes to colonization; however, because many bacteria are exogenous to patients’ normal flora, equipment may be a source of cross-contamination.




This article has been cited by other articles:


Home page
Am J Crit CareHome page
L. L. Feider, P. Mitchell, and E. Bridges
Oral Care Practices for Orally Intubated Critically Ill Adults
Am. J. Crit. Care., March 1, 2010; 19(2): 175 - 183.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. L. Sole, D. A. Penoyer, X. Su, E. Jimenez, S. J. Kalita, E. Poalillo, J. F. Byers, M. Bennett, and J. E. Ludy
Assessment of Endotracheal Cuff Pressure by Continuous Monitoring: A Pilot Study
Am. J. Crit. Care., March 1, 2009; 18(2): 133 - 143.
[Abstract] [Full Text] [PDF]


Home page
Clin. Microbiol. Rev.Home page
E. Foglia, M. D. Meier, and A. Elward
Ventilator-Associated Pneumonia in Neonatal and Pediatric Intensive Care Unit Patients
Clin. Microbiol. Rev., July 1, 2007; 20(3): 409 - 425.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
C. L. Cason, T. Tyner, S. Saunders, and L. Broome
Nurses' Implementation of Guidelines for Ventilator-Associated Pneumonia From the Centers for Disease Control and Prevention
Am. J. Crit. Care., January 1, 2007; 16(1): 28 - 37.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
C. J. Cutler and N. Davis
Improving Oral Care in Patients Receiving Mechanical Ventilation
Am. J. Crit. Care., September 1, 2005; 14(5): 389 - 394.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
W. Rabitsch, W. J. Kostler, W. Fiebiger, C. Dielacher, H. Losert, C. Sherif, T. Staudinger, E. Seper, W. Koller, F. Daxbock, et al.
Closed Suctioning System Reduces Cross-Contamination Between Bronchial System and Gastric Juices
Anesth. Analg., September 1, 2004; 99(3): 886 - 892.
[Abstract] [Full Text] [PDF]


Home page
J Am Med Inform AssocHome page
T. A Oniki, T. P Clemmer, and T A. Pryor
The Effect of Computer-generated Reminders on Charting Deficiencies in the ICU
JAMIA, March 1, 2003; 10(2): 177 - 187.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. L. Sole, J. F. Byers, J. E. Ludy, and C. L. Ostrow
Suctioning Techniques and Airway Management Practices: Pilot Study and Instrument Evaluation
Am. J. Crit. Care., July 1, 2002; 11(4): 363 - 368.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Association of Critical-Care Nurses.