AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Critical Care. 2003;12: 147-153

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Qureshi, M. A.
Right arrow Articles by Kruse, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Qureshi, M. A.
Right arrow Articles by Kruse, J. A.

Exposure of Intensive Care Unit Nurses to Nitric Oxide and Nitrogen Dioxide During Therapeutic Use of Inhaled Nitric Oxide in Adults With Acute Respiratory Distress Syndrome

By Mohammed A. Qureshi, MD, Nipurn J. Shah, MD, Carol W. Hemmen, RN, BSN, Mary C. Thill, RN, MSN and James A. Kruse, MD. From Wayne State University School of Medicine and Detroit Receiving Hospital, Detroit, Mich.

Background Although low concentrations of inhaled nitric oxide may by therapeutic, both nitric oxide and its oxidation product nitrogen dioxide are potentially toxic. The threshold limits for time-weighted average concentrations of nitric oxide and nitrogen dioxide issued by the American Conference of Governmental Industrial Hygienists are 25 and 3 ppm, respectively. The concentrations of these gases in the breathing space of hospital personnel during administration of nitric oxide to adult patients have not been reported.

Methods Air was sampled from the breathing zone of intensive care unit nurses via collar-mounted tubes during the nurses’ routine duties attending patients who were receiving inhaled nitric oxide at 5 or 20 ppm. The exhaust ports of the mechanical ventilators were left open to the room. Nitric oxide and nitrogen dioxide were chemically assayed as nitrite from sorbent tubes by using spectrophotometry. Ambient nitric oxide levels were measured at sequential distances from the ventilator by using chemiluminescence.

Results The time-weighted average concentrations of inspired gas for nurses during inhaled nitric oxide treatment were 0.45 ppm or less for nitric oxide and less than 0.29 ppm for nitrogen dioxide. Nitric oxide levels at the ventilator during delivery at 20 ppm were 9.2 ppm, but dropped off markedly beyond 0.6 m (2 ft), to a mean of about 30 ppb.

Conclusion Inhaled nitric oxide therapy at doses up to 20 ppm does not appear to pose a risk of excessive occupational exposure to nitric oxide or nitrogen dioxide to nurses during routine delivery of critical care.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Association of Critical-Care Nurses.