AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Critical Care. 2003;12: 343-348
Copyright © 2003 by the American Association of Critical-Care Nurses.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Wit, M.
Right arrow Articles by Epstein, S. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Wit, M.
Right arrow Articles by Epstein, S. K.

Administration of Sedatives and Level of Sedation: Comparative Evaluation via the Sedation-Agitation Scale and the Bispectral Index

By Marjolein de Wit, MD and Scott K. Epstein, MD. From the Pulmonary and Critical Care Division, New England Medical Center and Tufts University School of Medicine, Boston, Mass.

Objectives To compare levels of sedation in patients receiving continuous intravenous infusions of sedative/hypnotic or narcotic agents with levels in patients not receiving infusions and to compare subjective (Sedation-Agitation Scale) and objective (Bispectral Index) evaluations of sedation.

Methods Patients receiving mechanical ventilation in a medical intensive care unit were evaluated prospectively. Level of sedation was assessed with the Sedation-Agitation Scale (range 1–7, unarousable to dangerous agitation) and the Bispectral Index (range 0–100, flat line to awake waveform) recorded before and after stimulation. Patients were classified as receiving continuous infusions if an infusion had been administered within 24 hours preceding assessment.

Results Nineteen patients were evaluated on 80 occasions. Scores on the Sedation-Agitation Scale ranged from 1 to 5 (mean 2.6 and median 2) and correlated highly with values for the Bispectral Index (R2 = 0.48 before and 0.44 after stimulation, P < .001). Patients receiving continuous infusions were more deeply sedated than were patients receiving boluses or no medication (mean [SD] scores, Sedation-Agitation Scale: 2.1 [1.2] vs 3.3 [1.0], P < .001; Bispectral Index before stimulation: 63 [24] vs 86 [13], P < .001). Patients receiving continuous infusions were more likely to have a score of 2 or less on the Sedation-Agitation Scale (32/44 vs 8/35, P < .001).

Conclusion Objective and subjective assessments of sedation are highly correlated. Use of continuous infusions is associated with deeper levels of sedation, and patients receiving continuous infusions are more likely to be oversedated. Sedation therapy should be guided by subjective or objective assessment.




This article has been cited by other articles:


Home page
The Annals of PharmacotherapyHome page
J. M LeBlanc, J. F Dasta, and S. L Kane-Gill
Role of the Bispectral Index in Sedation Monitoring in the ICU
Ann. Pharmacother., March 1, 2006; 40(3): 490 - 500.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
K. J. Lafleur
Will Adequate Sedation Assessment Include the Use of Actigraphy in the Future?
Am. J. Crit. Care., January 1, 2005; 14(1): 61 - 63.
[Full Text] [PDF]


Home page
The Annals of PharmacotherapyHome page
B. D Watson and S. L Kane-Gill
Sedation Assessment in Critically Ill Adults: 2001-2004 Update
Ann. Pharmacother., November 1, 2004; 38(11): 1898 - 1906.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Association of Critical-Care Nurses.