AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


American Journal of Critical Care. 2005;14: 232-241
Copyright © 2005 by the American Association of Critical-Care Nurses.
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schell, K.
Right arrow Articles by Simpson, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schell, K.
Right arrow Articles by Simpson, K.

Clinical Comparison of Automatic, Noninvasive Measurements of Blood Pressure in the Forearm and Upper Arm

By Kathleen Schell, RN, DNSc, Elisabeth Bradley, RN, MS, APRN, BC, CCRN, Linda Bucher, RN, DNSc, Maureen Seckel, RN, MSN, APRN, BC, CCRN, Denise Lyons, RN, MSN, APRN, BC, Sandra Wakai, RN, BSN, CCRN, Deborah Bartell, RN, BSN, BC, Elizabeth Carson, RNC, Melanie Chichester, RNC, BSN, Teresa Foraker, RN, BSN and Kathleen Simpson, RNC, BSN. From Department of Nursing, University of Delaware (KS), and Christiana Care Health System (EB, LB, MS, DL, SW, DB, EC, MC, TF, KS), Newark, Del.

Background When the upper arm (area from shoulder to elbow) is inaccessible and/or a standard-sized blood pressure cuff does not fit, some healthcare workers use the forearm to measure blood pressure.

Objective To compare automatic noninvasive measurements of blood pressure in the upper arm and forearm.

Methods A descriptive, correlational comparison study was conducted in the emergency department of a 1071-bed teaching hospital. Subjects were 204 English-speaking patients 6 to 91 years old in medically stable condition who had entered the department on foot or by wheelchair and who had no exclusions to using their left upper extremity. A Welch Allyn Vital Signs 420 series monitor was used to measure blood pressure in the left upper arm and forearm with the subject seated and the upper arm or forearm at heart level.

Results Pearson r correlation coefficients between measurements in the upper arm and forearm were 0.88 for systolic blood pressure and 0.76 for diastolic blood pressure (P < .001 for both). Mean systolic pressures, but not mean diastolic pressures, in the upper arm and forearm differed significantly (t = 2.07, P = .04). A Bland-Altman analysis indicated that the distances between the mean values and the limits of agreement for the 2 sites ranged from 15 mm Hg (mean arterial pressure) to 18.4 mm Hg (systolic pressure).

Conclusions Despite strict attention to correct cuff size and placement of the upper arm or forearm at heart level, measurements of blood pressure obtained noninvasively in the arm and forearm of seated patients in stable condition are not interchangeable.




This article has been cited by other articles:


Home page
Clin Nurs ResHome page
K. L. Domiano, S. M. Hinck, D. L. Savinske, and K. L. Hope
Comparison of Upper Arm and Forearm Blood Pressure
Clin Nurs Res, November 1, 2008; 17(4): 241 - 250.
[Abstract] [PDF]


Home page
Crit Care NurseHome page
C. A. Rauen, M. Chulay, E. Bridges, K. M. Vollman, and R. Arbour
Seven Evidence-Based Practice Habits: Putting Some Sacred Cows Out to Pasture
Crit. Care Nurse, April 1, 2008; 28(2): 98 - 123.
[Full Text] [PDF]


Home page
Am J Crit CareHome page
K. Schell, D. Lyons, E. Bradley, L. Bucher, M. Seckel, S. Wakai, E. Carson, J. Waterhouse, M. Chichester, D. Bartell, et al.
Clinical Comparison of Automatic, Noninvasive Measurements of Blood Pressure in the Forearm and Upper Arm With the Patient Supine or With the Head of the Bed Raised 45{degrees}: A Follow-Up Study
Am. J. Crit. Care., March 1, 2006; 15(2): 196 - 205.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Association of Critical-Care Nurses.