AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drew, B.
Right arrow Articles by Wung, S.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Drew, B.
Right arrow Articles by Wung, S.
American Journal of Critical Care, Vol 5, Issue 3, 198-206
Copyright © 1996 by American Association of Critical Care Nurses


Articles

ST segment monitoring with a derived 12-lead electrocardiogram is superior to routine cardiac care unit monitoring

BJ Drew, MG Adams, MM Pelter, and SF Wung .

BACKGROUND: Prior studies have shown that a derived 12-lead electrocardiogram with a simple electrode configuration is comparable with the standard electrocardiogram for arrhythmia analysis. METHODS: A prospective, comparative, within subjects design was used to compare the value of the derived 12-lead electrocardiogram with that of routine monitoring of leads V1 and II for detection of transient myocardial ischemia in 250 patients treated for unstable angina or myocardial infarction. RESULTS: During 11,532 hours of derived 12-lead ST segment monitoring, 55 (22%) of 250 patients had 176 episodes of ischemia. Of the 55 patients with ischemia, 75% reported no chest pain and 64% had no ischemic ST changes with routine monitoring leads. All five patients who developed angiographically confirmed abrupt reocclusion after percutaneous transluminal coronary angioplasty had ischemic ST changes with the derived electrocardiogram (sensitivity, 100%), compared with only two patients with routine monitoring (sensitivity, 40%). Serious complications occurred in 17% of angina patients with ischemic events compared to 3% of those without ischemia. Length of stay in the cardiac care unit was twice as long in angina patients who had ischemic events. In patients with acute myocardial infarction, ischemic events were not associated with a more complicated hospital course; however, length of stay in the cardiac care unit was longer in patients with recurrent ischemia. CONCLUSIONS: The findings show that derived 12-lead ST monitoring is superior to routine monitoring of leads V1 and II for detecting transient myocardial ischemia. ST monitoring of the derived 12-lead electrocardiogram may identify high-risk patients with unstable angina and provide prognostic information that would not be otherwise available from the usual clinical measures.


This article has been cited by other articles:


Home page
Crit Care NurseHome page
C. A. Rauen, M. Chulay, E. Bridges, K. M. Vollman, and R. Arbour
Seven Evidence-Based Practice Habits: Putting Some Sacred Cows Out to Pasture
Crit. Care Nurse, April 1, 2008; 28(2): 98 - 123.
[Full Text] [PDF]


Home page
Crit Care NurseHome page
M. Jahrsdoerfer, K. Giuliano, and D. Stephens
Clinical Usefulness of the EASI 12-Lead Continuous Electrocardiographic Monitoring System
Crit. Care Nurse, October 1, 2005; 25(5): 28 - 37.
[Full Text] [PDF]


Home page
CirculationHome page
B. J. Drew, R. M. Califf, M. Funk, E. S. Kaufman, M. W. Krucoff, M. M. Laks, P. W. Macfarlane, C. Sommargren, S. Swiryn, and G. F. Van Hare
Practice Standards for Electrocardiographic Monitoring in Hospital Settings: An American Heart Association Scientific Statement From the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young: Endorsed by the International Society of Computerized Electrocardiology and the American Association of Critical-Care Nurses
Circulation, October 26, 2004; 110(17): 2721 - 2746.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. G. Adams-Hamoda, M. A. Caldwell, N. A. Stotts, and B. J. Drew
Factors to Consider When Analyzing 12-Lead Electrocardiograms for Evidence of Acute Myocardial Ischemia
Am. J. Crit. Care., January 1, 2003; 12(1): 9 - 16.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. M. Pelter, M. G. Adams, and B. J. Drew
Association of Transient Myocardial Ischemia With Adverse In-Hospital Outcomes for Angina Patients Treated in a Telemetry Unit or a Coronary Care Unit
Am. J. Crit. Care., July 1, 2002; 11(4): 318 - 325.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
B. J. Drew
Celebrating the 100th Birthday of the Electrocardiogram: Lessons Learned From Research in Cardiac Monitoring
Am. J. Crit. Care., July 1, 2002; 11(4): 378 - 386.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
B.J. Drew, M.M. Pelter, and M.G. Adams
Frequency, characteristics, and clinical significance of transient ST segment elevation in patients with acute coronary syndromes
Eur. Heart J., June 2, 2002; 23(12): 941 - 947.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1996 by the American Association of Critical-Care Nurses.