AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kiely, M
Right arrow Articles by Carroll, D
Right arrow Search for Related Content
PubMed
Right arrow Articles by Kiely, M
Right arrow Articles by Carroll, D
American Journal of Critical Care, Vol 7, Issue 6, 436-438
Copyright © 1998 by American Association of Critical Care Nurses


Articles

Thermodilution measurement of cardiac output in patients with low output: room-temperature versus iced injectate

M Kiely, LA Byers, R Greenwood, E Carroll, and D Carroll .

BACKGROUND: Measurements of cardiac output with the thermodilution technique add to data for clinical decision making and therefore must be valid and reliable. However, the results of studies on the accuracy of values obtained with room-temperature and iced injectates, especially in patients with high or low cardiac output, have been conflicting. OBJECTIVE: To determine the effect of the temperature of the injectate (iced or room temperature) on cardiac output values obtained with the thermodilution technique in critically ill adults with known low cardiac output. METHODS: A convenience sample of 50 subjects (41 men and 9 women) who had a cardiac index of less than 2.5 (calculated as cardiac output in liters per minute divided by body surface area in square meters) before the study had cardiac output measured by using a closed system and manual injections of room-temperature and iced injectates. RESULTS: A paired t test indicated no significant difference between iced and room-temperature injectates for cardiac output (iced, 3.62 L/min; room temperature, 3.71 L/min; t = 0.99; P = .327) and cardiac index (iced, 1.95; room temperature, 1.99; t = 0.71; P = .482). CONCLUSION: The findings support the practice of using room-temperature injectate to measure cardiac output in patients with low cardiac output.


This article has been cited by other articles:


Home page
Am J Crit CareHome page
M. Engoren and D. Barbee
Comparison of Cardiac Output Determined by Bioimpedance, Thermodilution, and the Fick Method
Am. J. Crit. Care., January 1, 2005; 14(1): 40 - 45.
[Abstract] [Full Text] [PDF]