AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fincher, R.
Right arrow Articles by Jackson, J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Fincher, R.
Right arrow Articles by Jackson, J.
American Journal of Critical Care, Vol 7, Issue 6, 439-443
Copyright © 1998 by American Association of Critical Care Nurses


Articles

Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters

RK Fincher, JS Strong, and JL Jackson .

OBJECTIVE: To compare measurements of hemoglobin and potassium in blood samples obtained from peripheral venous catheters with measurements in samples obtained via venipuncture. SUBJECTS: 53 adult volunteer patients admitted to a medical ward. METHODS: For each patient, a 10-mL blood sample was obtained from a 20-gauge or larger peripheral venous catheter after a 3-mL volume of fluid was discarded. Immediately afterward, additional samples were obtained by venipuncture, and all samples were sent to the laboratory for measurement of hemoglobin and potassium levels. Separate venipuncture samples were obtained from both extremities in another 10 subjects to assess intratechnique variation. Results were analyzed by using limits-of-agreement analysis. RESULTS: Blood samples were successfully obtained from a peripheral catheter in 32 (60%) of the 53 patients. The success rate was 78% with 18-gauge catheters and 42% with 20-gauge catheters (P = .021). The 95% agreement interval in the set of differences between values for samples obtained via catheter and samples obtained via venipuncture was +/- 0.37 mmol/L for potassium and +/- 7.6 g/L for hemoglobin. The 95% agreement interval for the venipuncture control group was +/- 0.21 mmol/L for potassium and +/- 7.3 g/L for hemoglobin. The preset acceptable interval for potassium measurements was +/- 0.3 mmol/L, and that for hemoglobin measurements was +/- 10 g/L. CONCLUSIONS: Obtaining blood samples from peripheral catheters is an acceptable alternative to venipuncture for hemoglobin measurements but not for potassium measurements. Larger gauge catheters are better than small-gauge catheters for obtaining blood samples.