AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow View Responses to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carroll, K.
Right arrow Articles by Tarazi, R.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Carroll, K.
Right arrow Articles by Tarazi, R.
American Journal of Critical Care, Vol 7, Issue 6, 444-449
Copyright © 1998 by American Association of Critical Care Nurses


Articles

Risks associated with removal of ventricular epicardial pacing wires after cardiac surgery

KC Carroll, LM Reeves, G Andersen, FM Ray, PL Clopton, M Shively, and RY Tarazi .

BACKGROUND: Epicardial pacing wires are routinely used for the diagnosis and treatment of bradyarrhythmias after cardiac surgery. The frequency of arrhythmias during removal of the wires is unknown, and methods of removal vary among institutions. OBJECTIVES: To describe the frequency of ventricular arrhythmias during removal of epicardial pacing wires from the right ventricle, to determine variables that are predictive of ventricular arrhythmias during wire removal, and to describe patients' perceptions of wire removal. METHODS: A convenience sample of 145 patients who had undergone cardiac surgery was studied during the course of 1 year. Electrocardiographic and vital signs were recorded throughout wire removal. Patients' records were reviewed for variables that could predict the occurrence of arrhythmias during wire removal: laboratory values, history of arrhythmias, medications, medical history, postoperative course, and pain reported by the patient. RESULTS: Sixty-six percent of patients had one premature ventricular contraction or more while the ventricular wires were being removed. Seven percent of patients had nonsustained ventricular tachycardia during wire removal. Patients who had repeat cardiac surgery had significantly more nonsustained ventricular tachycardia than did all other patients (P < .01). Only a history of heart failure (P < .02) was a significant predictor of premature ventricular contractions during wire removal. On a scale of 0 (no pain) to 10 (worst pain), the mean rating of pain intensity reported by patients was 2.39 (SD = 2.77). CONCLUSION: Patients may be at risk for ventricular arrhythmias during removal of epicardial pacing wires. Findings support the need for electrocardiographic monitoring while pacing wires are being removed.


eLetters:

Read all eLetters

Death From Removal?
Gerard A. Simak
AJCC Online, 2 Feb 2007 [Full text]
Response: Death From Wire Removal?
Karen Carroll
AJCC Online, 13 Jun 2007 [Full text]