AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Glass, C
Right arrow Articles by Sessler, C.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Glass, C
Right arrow Articles by Sessler, C.
American Journal of Critical Care, Vol 8, Issue 2, 93-100
Copyright © 1999 by American Association of Critical Care Nurses


Articles

Endotracheal tube narrowing after closed-system suctioning: prevalence and risk factors

C Glass, MJ Grap, and CN Sessler .

BACKGROUND: Few data exist about buildup of secretions within endotracheal tubes of patients treated with closed-system suctioning in the intensive care unit. OBJECTIVES: To describe the extent, prevalence, and distribution of narrowing of endotracheal tubes related to buildup of secretions and to determine contributing factors. METHODS: Forty endotracheal tubes were examined within 4 hours of extubation, after at least 72 hours of use. Data on patients' daily weight and fluid balance, ventilator humidification temperatures, and nurses' descriptions of secretions during the 3 days preceding extubation were recorded. Any secretion debris in the endotracheal tubes was weighed. At 1-cm intervals along the tube, the debris was described and the depth of the debris was measured to the nearest 0.5 mm. RESULTS: Mean duration of intubation was 6.6 days. Two tubes had no debris. Mean overall depth of debris was 0.64 mm, mean greatest depth was 2.0 mm (range, 0-5 mm), and mean weight was 1.16 g. The entire tube was affected, with the greatest depth of debris at the 6- to 9-cm and 13- to 14-cm markings. Duration of intubation correlated with mean greatest depth of debris (r = 0.37, P = .02), mean overall depth of debris (r = 0.48, P = .002), and mean weight of debris (r = 0.38, P = .02). CONCLUSIONS: Endotracheal tubes are markedly narrowed by the buildup of secretions after closed-system suctioning. Duration of intubation, but not endotracheal tube size or amount of secretions, was associated with the degree of narrowing.


This article has been cited by other articles:


Home page
Crit Care NurseHome page
T. Unoki, A. Serita, and M. J. Grap
Automatic Tube Compensation During Weaning From Mechanical Ventilation: Evidence and Clinical Implications
Crit. Care Nurse, August 1, 2008; 28(4): 34 - 42.
[Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
T. Mirkovic, V. Paver-Erzen, T. Klokocovnik, A. Gursahaney, P. Hernandez, and S. B. Gottfried
Tracheal pressure regulated volume assist ventilation in acute respiratory failure: [Ventilation debit-assistee regulee par pression tracheale dans les cas d'insuffisance respiratoire aigue]
Can J Anesth, June 1, 2007; 54(6): 420 - 429.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
O. Stenqvist
Practical assessment of respiratory mechanics
Br. J. Anaesth., July 1, 2003; 91(1): 92 - 105.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Association of Critical-Care Nurses.