AJCC
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Powers, J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Powers, J.
American Journal of Critical Care, Vol 8, Issue 4, 250-253
Copyright © 1999 by American Association of Critical Care Nurses


Articles

Obtaining blood samples for coagulation studies from a normal saline lock

JM Powers .

OBJECTIVES: To determine the amount of blood that should be discarded from a peripheral normal saline lock, a capped-off intravenous port, before a blood sample is obtained for determination of activated partial thromboplastin time from patients being treated with heparin. METHODS: A prospective, quasi-experimental design was used with 32 patients. A blood sample was obtained via venipuncture from each patient to serve as the control for that patient. The normal saline lock was flushed with 2 mL of normal saline. Four consecutive 3-mL blood samples were obtained directly from the normal saline lock, representing samples obtained after discard volumes of 0, 2, 4, and 6 times the dead space of the catheter and extension set (1.5 mL). Activated partial thromboplastin times for the venipuncture blood sample were compared with the times for the blood samples obtained from the normal saline lock. RESULTS: The only significant difference (P = .02) was that activated partial thromboplastin time was 15% higher in the blood sample obtained from the normal saline lock with no blood discarded than in the venipuncture blood sample. CONCLUSIONS: Nurses can obtain accurate measurements of activated partial thromboplastin time with blood samples obtained from normal saline locks by first discarding a volume of blood equal to 2 times the dead space of the catheter and extension set. Obtaining blood samples in this manner reduces patients' discomfort due to repeated venipuncture and diminishes blood loss.


This article has been cited by other articles:


Home page
Crit Care NurseHome page
L. K. K. Prue-Owens
Use of Peripheral Venous Access Devices for Obtaining Blood Samples for Measurement of Activated Partial Thromboplastin Times
Crit. Care Nurse, February 1, 2006; 26(1): 30 - 38.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Association of Critical-Care Nurses.