American Journal of Critical Care. 2003;12: 220-230
Copyright © 2003 by the American Association of Critical-Care Nurses.
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Right arrow Take the CE Test
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sole, M. L.
Right arrow Articles by Brummel, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sole, M. L.
Right arrow Articles by Brummel, K.

CE Article

A Multisite Survey of Suctioning Techniques and Airway Management Practices

By Mary Lou Sole, RN, PhD, CCNS, Jacqueline F. Byers, RN, PhD, CNAA, Jeffery E. Ludy, EdD, RRT, Ying Zhang, PhD, Christine M. Banta, RN, MSN, CCRN and Kathy Brummel, BS, CRT. From the University of Central Florida, Orlando, Fla.


    Abstract
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Background Ventilator-associated pneumonia, common in critically ill patients, is associated with microaspiration of oropharyngeal secretions and may be related to suctioning and airway management practices.

Objectives To describe institutional policies and procedures related to closed-system suctioning and airway management of intubated patients, and to compare practices of registered nurses and respiratory therapists.

Methods A descriptive, comparative, multisite study of facilities that use closed-system suctioning devices on most intubated adults was conducted. Nurses and respiratory therapists who worked at the sites completed surveys related to their practices.

Results A total of 1665 nurses and respiratory therapists at 27 sites throughout the United States responded. The typical respondent had at least 6 years’ experience with patients receiving mechanical ventilation (61%) and a baccalaureate degree or higher (54%). Most sites had policies for management of endotracheal tube cuffs (93%), hyperoxygenation (89%) and use of gloves (70%) with closed-system suctioning, and instillation of isotonic sodium chloride solution for thick secretions (74%). Only 48% of policies addressed oral care and 37% addressed oral suctioning. Nurses did more oral suctioning and oral care than respiratory therapists did, and respiratory therapists instilled sodium chloride solution more and rinsed the suctioning device more often than nurses did.

Conclusions Policies vary widely and do not always reflect current research. Consistent performance of practices such as wearing gloves for airway management and maintaining endotracheal cuff pressures must be evaluated. Collaborative, research-based policies and procedures must be developed and implemented to ensure best practices for intubated patients.

Notice to CE enrollees:
A closed-book, multiple-choice examination following this article tests your understanding of the following objectives:
  1. Describe the reasons why frequent oropharyngeal suctioning is important before repositioning an endotracheal tube
  2. Identify the contributing factors related to ventilator-associated pneumonia
  3. Describe the different methods of oral care and the importance it plays in ventilator-associated pneumonia


Airway management is an important aspect of care for patients who require mechanical ventilation. This management includes maintenance of the artificial airway, endotracheal suctioning, clearance of oral and nasal secretions by suctioning, oral care, and management of equipment. Endotracheal suctioning practices have changed in the past several years, with many institutions using closed-system suctioning (CSS) to reduce hypoxemia and other complications associated with suctioning.1 Because CSS is designed to clear secretions from only the lower part of the airway, practices once associated with traditional single-catheter suctioning techniques have been eliminated. Changes inherent in CSS technique may result in less oral suctioning and in cross-contamination of equipment because suction tubing and canisters are often used for both CSS and oral suctioning.2,3 We conducted this study of suctioning techniques and airway management practices (STAMP) to determine institutional policies for CSS and airway management, and to identify airway management practices reported by registered nurses and respiratory care staff members who regularly care for patients receiving mechanical ventilation and use CSS. Limited information related to CSS and airway management has been published in practice guidelines.4–6


{blacksquare} Airway management practices, including closed-system suctioning, affect patients’ outcomes and are the combined responsibility of nurses and respiratory therapists.

 


    Background and Significance
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Patients receiving mechanical ventilation are at highest risk of developing pneumonia. Ventilator-associated pneumonia (VAP) is a parenchymal lung infection that occurs more than 48 hours after initiation of mechanical ventilation.7 VAP develops in about 25% of patients, with reported occurrences ranging from 8% to 65%.8–14 The Centers for Disease Control and Prevention report median VAP rates of 4.2 to 16.3 cases per 1000 ventilator days in adult critical care units.15 Risk factors for VAP include intubation and certain conditions, such as trauma and burns.10,14,16 VAP increases hospital length of stay by 16 to 17 days and increases costs by almost $30 000 per case.14,17 When VAP occurs, the likelihood of death increases 2- to 4-fold.13,17

VAP is caused by aspiration of oropharyngeal and/or gastrointestinal secretions, direct inoculation, and inhalation of bacteria.4 The endotracheal tube bypasses normal defense mechanisms and contributes to aspiration of secretions. Microaspiration of bacteria in oropharyngeal secretions is the most common cause of VAP and is associated with dental plaque, invasive devices, and respiratory care equipment.4,11,16,18

Airway management practices may contribute to VAP.19 Knowledge of institutional policies will help identify gaps in practice, and knowledge of staff practices will determine adherence to institutional policies and published recommendations. In this article, we describe similarities and differences in practices of nurses and respiratory therapists and discuss the importance of establishing collaborative policies and procedures to improve patients’ outcomes.


    Purposes
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
This study was intended to describe current policies and procedures for STAMP and to compare reported airway management practices of nurses and respiratory therapists. Specific purposes were as follows:


    Methods
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
We used survey methods to conduct a descriptive, comparative, multisite study. A goal was to enroll 30 sites that could recruit 1200 staff members to complete the STAMP: Individual Survey (960 nurses and 240 respiratory therapists). Sample size was estimated to achieve 80% power based on a small effect and .05 level of significance achieved in the pilot study (proportion comparison statistics). The institutional review board at the University of Central Florida approved the study.


{blacksquare} A national survey was used to collect data on institutional policies and on individual practices related to airway management among nurses and respiratory therapists.

 


    Sampling
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Using network sampling, we recruited sites from throughout the United States to participate. Sites were recruited via electronic mail messages to colleagues, as well as postings to the Society of Critical Care Medicine Advanced Practice Nursing listserv. We asked persons who received the "call for participation" to forward the request to other colleagues who might be interested in the study. The criterion for sites to participate was that CSS be used on more than 50% of intubated patients. Staff participants were the nurses and respiratory therapists who care for intubated adult patients and regularly use CSS for endotracheal suctioning.


    Instruments
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
We used 2 instruments to collect data: STAMP: Institutional Policies and Data, consisting of 45 multiple-choice and fill-in questions; and STAMP: Individual Survey for nurses and respiratory therapists, consisting of 32 multiple-choice questions and 1 fill-in question printed on a scannable form. All instruments were coded to maintain anonymity and confidentiality of responses. Before this study, a pilot study was conducted at 4 sites with 132 nurses and respiratory therapists responding. Content validity for both instruments was established by a panel of 3 persons with expertise in nursing, respiratory care, and survey methods. Test-retest reliability was .82.3


    Procedures
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Sites were recruited in May and June 2001. Site coordinators received a detailed operations manual and were responsible for obtaining approvals; completing the STAMP: Institutional Policies and Data instrument; and distributing and collecting STAMP: Individual Surveys from nurses and respiratory therapists. Envelopes were provided for each survey so that confidentiality of responses could be maintained. Once approval was obtained, the site coordinators collected data during a 2- to 3-week period. Data collection was completed in October 2001.


    Results
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Description of Sample
Thirty sites were recruited to participate. Of these, 3 sites withdrew because of time constraints, resulting in 27 sites. All geographical areas were represented; however, most sites (70%) were located in northeastern and southeastern states. The number of beds in the institutions ranged from 84 to 960, with a median of 500. Personnel resources available to provide expertise in the care of intubated patients included clinical nurse specialists (74%), unit-based educators (52%), and respiratory therapy educators (52%).


{blacksquare} Most sites had policies for endotracheal cuff management and closed-system suctioning. Although not supported by previous studies, most policies included instillation of isotonic sodium chloride solution for thick secretions.

{blacksquare} Practices concerning oral care procedures, including oral suctioning, vary widely.

 

The response rate for staff members was 55%. Usable responses on the Individual Survey are reported for 1665 staff members: 1186 nurses (71%) and 479 respiratory therapists (29%). Table 1Go provides a summary of demographic information for the staff participants.


View this table:
[in this window]
[in a new window]
 
Table 1 Description of staff members who participated in the study

 
Institutional Policies and Procedures Related to Airway Management
  Responsibility.   Responsibility for writing airway management policies varied. At most sites, nurses wrote policies related to oral care, respiratory therapists wrote the policies related to endotracheal tube management, and collaborative policies were written for endotracheal suctioning. Five sites (19%) had separate policies written by nursing and respiratory care staff.

  Policies and Procedures.   Table 2Go summarizes the percentage of sites that had written policies on specific practices. Most sites had policies that addressed changing the CSS, use of gloves, and procedures for management of endotracheal cuffs. Less than half of the sites had policies for oral care, oral and nasal suctioning, suctioning above the endotracheal tube cuff before repositioning the tube, and changing bite blocks or oral airways. Instillation of isotonic sodium chloride solution is recommended for thick secretions at 74% of the sites.


View this table:
[in this window]
[in a new window]
 
Table 2 Suctioning and airway management practices included in institutional policies

 
  Equipment.   CSS devices are used on all intubated patients at 59% of the facilities. At the other sites, CSS is used if specific criteria are met: high positive end-expiratory pressure (15%), patient’s condition unstable without mechanical ventilation (15%), need for frequent endotracheal suctioning (11%), intubation longer than 24 hours (11%), or infection (7%).

The CSS catheters are changed every 24 to 48 hours at 63% of sites. The other sites change the CSS every 72 hours, "as needed," or weekly. A respiratory therapist is responsible for changing the CSS device at nearly all sites (93%).

Most sites (82%) use a single suction tubing and collection canister for both CSS and oral suctioning. The single tubing is connected as needed to either the CSS or the oral suctioning device. The remaining sites use designated equipment for CSS and oral suctioning via a Y-connector setup to 1 canister, or separate canisters and tubings for each procedure. The suction tubing is changed "only as needed" at the majority (59%) of sites. Tonsil suction devices that are reused for variable periods are used for oral suctioning at 89% of sites.

  Endotracheal Tube Management.   Most policies specify that respiratory therapists are to measure and record endotracheal tube cuff pressures every 8 to 12 hours (81%). The method for determining optimal cuff pressures varied. Nearly half (48%) recommend the minimal leak technique for maintaining endotracheal cuff pressures. Twelve sites (44%) specify a minimum cuff pressure of 15 to 25 cm H2O. Policies at 48% of sites recommend that oral endotracheal tubes be repositioned every 24 to 48 hours to avoid pressure damage from securing the oral tubes.

  Oral Care.   More than half of hospitals do not have specific policies for oral care of intubated patients; however, a variety of products are available. Oral swabs are available at all sites, and more than half have mouth care kits with oral swabs and cleansing solution. Only 10 sites (37%) reported that toothbrushes and toothpaste are available. Other products include mouthwash (41%), suction swabs (30%), and chlorhexidine mouth rinse (15%, by prescription).

VAP Rates and Organisms
Only 14 sites (52%) reported VAP rates. Many sites stated that their institution did not track VAP rates. The mean VAP rate was 6.7 (range, 0.84–20) cases per 1000 ventilator days. At most sites, VAP is diagnosed by using the clinical criteria of the Centers for Disease Control and Prevention. The top 5 organisms responsible for VAP were Pseudomonas aeruginosa, Enterobacter species, methicillin-resistant Staphylococcus aureus, methicillin-sensitive S aureus, and Klebsiella pneumoniae.

Practices of Nurses and Respiratory Therapists
Staff members were asked how often they performed several CSS and airway management activities. Response options included "always," "most of the time," "half of the time," "rarely," and "never." Data were recoded into 3 categories to facilitate data analysis: "majority of time," "half of the time," and "not very often." Chi-square statistics were computed to compare practices between nurses and respiratory therapists. When significant differences in practices were found (P<=.05), the 95% CIs for the difference of the percentages between nurses and respiratory therapists were calculated to determine who performs the stated procedures more often.

Table 3Go gives the percentage of staff members who perform the stated activities the majority of time. Respiratory therapists instill isotonic sodium chloride solution, rinse the CSS device after suctioning, and suction above the endotracheal tube cuff when repositioning the tube more often than nurses do. Nurses suction the mouth more often after CSS than respiratory therapists do. Use of gloves is common; 89% of staff wear gloves the majority of the time when performing CSS.


View this table:
[in this window]
[in a new window]
 
Table 3 Percentages of staff members who perform selected practices the majority of the time

 
Table 4Go summarizes additional information related to suctioning and airway management practices of staff members. Nurses perform oral suctioning, oral care with swabs, and tooth brushing more often than respiratory therapists do. Many nurses did not know how often endotracheal cuff pressures were measured (38%) or the method for maintaining cuff pressures (46%).


View this table:
[in this window]
[in a new window]
 
Table 4 Comparison of percentages of nurses and respiratory therapists who perform selected airway management practices

 
Staff members were also asked their opinion of the effectiveness of CSS devices. The majority of staff members (79%) stated that CSS is the same as or better than traditional open suctioning.

Factors Influencing Practice
Staff members were asked what factors most influenced their CSS and airway management practices. They were instructed to mark all options that were relevant (Table 5Go). The majority of respiratory therapists stated that their practice is most influenced by their basic educational program. Practice of nurses is influenced most by preceptors and knowledge obtained in the basic educational preparation. Significant differences were noted between the disciplines on several factors by {chi}2 statistics.


View this table:
[in this window]
[in a new window]
 
Table 5 Percentages of nurses and respiratory therapists indicating factors that influenced their suctioning and airway management practices*

 

    Discussion
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Policies
Policies for STAMP varied within and between institutions. Several sites reported that both nursing and respiratory therapy wrote separate policies for many items related to STAMP. This factor could lead to a disparity in practice. Many items were not included in written policies, such as oral care and suctioning. We found similar responses in our pilot study.3 Nurses and respiratory therapists reported a variety of practices and did not always follow institutional policies and procedures.

Closed Suctioning Equipment
Most sites change the CSS devices every 24 to 48 hours. In a recent study,20 changing the catheters on an as-needed basis significantly reduced costs and did not affect the incidence of nosocomial pneumonia. The CSS becomes colonized as soon as it is used for endotracheal suctioning, but no differences in rates of VAP between open suctioning and CSS have been found.21–25 In one study,26 rates of VAP were reduced with CSS.

A single suction tubing and canister is used for both CSS and oral suctioning at most sites. This practice causes a break in the "closed" system when equipment is used for oral suctioning. Possibly cross-contamination from the oral suction device to the CSS device occurs.2 Dual tubings with a Y-connector are available from CSS manufacturers and are used at some sites; their effect on reducing infection is not known.

VAP Rates and Organisms
The National Nosocomial Infection Surveillance System of the Centers for Disease Control and Prevention compiles VAP rates from hospitals all over the United States. The mean VAP rate reported by that system is 10.6 episodes per 1000 ventilator days. The sites in this study reported lower rates: 6.7 per 1000 ventilator days. The top 5 organisms for VAP reported by the sites are similar to those reported in the literature.15

CSS Policies and Practices
Results of a recent study1 show that many institutions did not have policies for CSS. In the STAMP study, most institutions had policies for changing the CSS devices, hyperoxygenation before suctioning, rinsing the CSS device after use, and use of gloves. Although use of CSS lessens suction-induced hypoxemia, it is important that hyperoxygenation be included in CSS procedures, depending on the assessment of the patient.22,27–29

Most respondents reported establishing hyper-oxygenation before CSS the majority of the time. Findings are higher than those reported in other studies1,3 and may be attributed to the higher number of institutions that include hyperoxygenation in their policies. Most staff members rinse the CSS catheter after use; however, respiratory therapists perform this practice more often than nurses. One possible reason for this difference is that respiratory therapists instill isotonic sodium chloride solution during suctioning more often than nurses do, so a vial is attached to the instillation/rinsing port of the CSS, which facilitates rinsing. Rinsing the CSS device may also be emphasized more in respiratory therapy programs.

One third of sites include hyperinflation in CSS procedures, and 15% of staff members report that they establish hyperinflation during CSS. This percentage is lower than previously reported.1,3 It is not known if hyperinflation is needed with CSS.1

Similar to the results of our pilot study,3 only 4% of the respondents regularly disconnect the CSS device and suction via traditional open suctioning. These findings are lower than previously reported1 and may be related to overall satisfaction with the effectiveness of CSS. Traditional suctioning is not advocated because it disrupts the closed system, potentially increasing the risk for infection. Open suctioning also negates the beneficial effects of CSS, such as prevention of hypoxemia and maintenance of positive end-expiratory pressure.

Instillation of Isotonic Sodium Chloride Solution
Most sites (74%) have policies that include instillation of isotonic sodium chloride solution for thick secretions. This finding mirrors that of our pilot study.3 Respiratory therapists were twice as likely as nurses to report instillation of sodium chloride solution the majority of the time (51% vs 26%). Schwenker et al30 reported that 64% of nurses in a large teaching hospital rarely instill isotonic sodium chloride solution before suctioning, whereas 71% of respiratory therapists often do. Other researchers have reported similar findings.3,31,32 Adverse effects of such instillation have been reported (primarily in nursing journals), along with recommendations to avoid this practice.33–38 Despite these published reports, staff continue to instill sodium chloride solution. One reason for the finding may be that most staff members (83%) do not base their practice on published reports. In addition, instillation of sodium chloride solution for thick secretions is still recommended in textbooks, and many nurses and respiratory therapists think that such instillation is needed as a clinical intervention for thick secretions.39 A controlled clinical trial related to effectiveness of instillation of sodium chloride solution and its adverse effects is warranted because many of the studies lack controls and have a small number of subjects.

Oral Care
Less than half (48%) of the sites had written policies for oral care of intubated patients. None of the 4 sites in our pilot study had oral care policies.3 Current critical care nursing manuals40–42 advocate oral care from every 2 hours to every shift (8–12 hours) to prevent overgrowth of normal flora.

Most nurses (72%) stated that they perform mouth care every 4 hours with oral swabs. However, only 39% of nurses brush patients’ teeth on a routine basis, less than that reported in our pilot study (58%).3 In another recent study,2 67% of patients had not had oral care within the past 4 hours. Fewer respiratory therapists participate in oral care; only 21% of respiratory therapists use swabs on a regular basis, and 6% reported that they brush patients’ teeth. Oral care is taught in beginning nursing courses, but it may not be emphasized as an important component of airway management for patients receiving mechanical ventilation. Oral care is considered a nursing responsibility by most disciplines, accounting for the differences in practice between nurses and respiratory therapists.

Oral swabs are used for mouth care more often than brushing teeth is used. Swabbing may be effective for quick cleansing or moistening the mouth, but it does not substitute for brushing teeth. Swabbing takes much less time than brushing teeth, which may be a reason for this finding. Another reason may be the lack of available equipment to brush patients’ teeth. Only 37% of sites stated that toothbrushes were available for patients, and 1 of these sites stated that toothbrushes came from volunteer services rather than being readily available in unit supplies.

The American Association for Critical-Care Nurses’ Protocols for Practice6 recommend oral care via swabbing, brushing teeth, and suctioning oral secretions "several times a day" to prevent plaque and periodontal disease. Munro and Grap18 reported that plaque increased during a 7-day period after intubation and proposed a relationship between plaque and VAP. In recent studies,43,44 VAP was reduced by oral decontamination with topical agents. Because oral hygiene may play a role in oral colonization and VAP, brushing teeth is an important intervention for patients receiving mechanical ventilation. The optimal frequency and method of oral care for promoting patients’ comfort and preventing VAP are not known.

Oral Suctioning
Microaspiration is a risk factor for VAP.4 In addition to bypassing normal defenses, the endotracheal tube may also damage the larynx, increasing the risk for aspiration.45 By decreasing the amount of secretions, suctioning bacterial-laden oral and subglottic secretions may help prevent VAP. Policies related to the frequency of oral suctioning and to suctioning above the endotracheal tube before repositioning the tube had been written at only half of the sites.

Oral suctioning is an integral part of the suctioning process when traditional open suctioning is done with single-use suction catheters. The advent of CSS techniques has changed the way oral suctioning is done. Additional equipment is needed to carry out oral suctioning when the CSS device is used, and staff members must recognize the need for oral suctioning. In our study, respiratory therapists were less likely than nurses to suction oral secretions, perhaps because oral suctioning is not an integral part of CSS, or because nurses performed more oral care. If staff members do not routinely suction patients’ oropharyngeal secretions, the volume of secretions that may be aspirated increases.

Oral suctioning with CSS is addressed in only a few articles and text chapters.41,46 Oral suctioning is considered "ongoing monitoring" rather than a part of suctioning procedures,6 and this procedure is not addressed in respiratory therapy texts.39,47 Product instructions from the leading CSS manufacturers do not mention the need for oral suctioning. However, companies market suction tubing and supplies for oral suctioning that can be used along with CSS. Suction catheters designed for subglottic aspiration of secretions also are available.

Management of Endotracheal Tube Cuffs
Most sites had written policies for how endotracheal cuffs are managed and the frequency for measuring cuff pressures. Respiratory therapists followed institutional policies related to endotracheal cuff management. Frequency of measuring endotracheal cuff pressures varied from every 2 hours to every 12 hours, and the most common response (45% of respiratory therapists) was every 12 hours. In our pilot study, endotracheal cuff pressures were recorded every 8 hours.3 Current respiratory therapy and critical care resources recommend that clinicians monitor endotracheal cuff pressures every 8 to 12 hours and as needed.48–50 However, in a recent study,51 a decrease in cuff pressures occurred within a 4-hour period. More frequent monitoring may be needed to detect leaks of endotracheal tube cuffs and assist in maintaining adequate cuff pressures.

Many nurses did not know how often cuff pressures are measured (38%) or how endotracheal cuff pressures are maintained (46%). These findings were also noted during the pilot study.3 Endotracheal cuff management is often considered a respiratory therapy procedure, so content related to endotracheal cuff management may not be addressed in nursing texts and courses.

Nearly half of respiratory therapists stated that they manage endotracheal cuffs by using a minimal leak technique, whereas the others maintain the cuff at a minimum pressure ranging from 15 to 25 cm H2O. The goal is to keep the cuff pressures below the tracheal mucosal perfusion pressure, which is estimated to range between 20 and 25 mm Hg, or between 24 52Underinflation facilitates aspiration and 30 cm H2O. of subglottic and oropharyngeal secretions into the lower airway, increasing the risk of VAP.53 Rello et al54 found that patients with endotracheal cuff pressures less than 20 cm H2O had a 2.5-fold increase in VAP rates. Only 41% of respiratory therapists stated that they keep the pressure at 20 cm H2O or greater. Eleven percent of respiratory therapists stated that they keep cuff pressures at 15 cm H2O, a level that might increase the risk of VAP. These findings are similar to what we noted in our pilot study.3

Seventy-two percent of all staff members stated that they suction above the endotracheal cuff before repositioning an oral endotracheal tube the majority of the time. In our pilot study,3 only 50% of the staff reported regularly suctioning above the endotracheal cuff. Suctioning above the endotracheal cuff before repositioning an oral endotracheal tube reduces the volume of secretions that may be aspirated, and this procedure should be emphasized in policies and practices.

Equipment
Most hospitals had policies related to frequency of changing suction tubing and the oral suction device (Yankauer). These numbers are higher than previously reported.3 However, policies for rinsing and storing the Yankauer and for changing oral airways or bite blocks were not usually written. Staff members report variable practices for changing Yankauer devices, ranging from every 24 hours (39%) to only as needed (36%). Nine percent use disposable suction swabs.

Most staff members change bite blocks only as needed. Oral airways should be removed every 24 hours or as needed to allow for complete oral hygiene and inspection of the oral cavity.48

In a recent study,2 Yankauer devices harbored potentially pathogenic bacteria within 24 hours; however, it is not known if these bacteria contribute to VAP. More than half (53%) of staff members rinse the Yankauer devices with sterile sodium chloride solution, a practice supported by the Centers for Disease Control and Prevention.4 However, 30% of staff members rinse the devices with tap water, a practice that has been associated with outbreaks of bacteria,4 and 6% do not rinse the devices at all. Most staff members store the Yankauer device on a shelf in its original package. Similarly, in a recent observational study,2 66% of Yankauer devices were found on the shelf, and the majority of devices were not covered.

Perception of the Effectiveness of CSS
Seventy-nine percent of staff stated that CSS was the same as or better than traditional open suctioning, similar to what we found in our pilot study.3 Because CSS was used on the majority of patients, most likely staff members are comfortable using this type of suctioning system. These reports of high satisfaction are higher than those cited by Blackwood31 and Blackwood and Webb,55 who reported ineffective removal of secretions 45% of the time with CSS because of thick secretions. Those studies31,55 were done in Ireland, where practices related to rinsing the CSS and/or using humidification may be different.


    Implications
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Factors influencing airway management practices varied and differed between nurses and respiratory therapists. A person’s basic educational program is a strong influence on practice. Therefore, it is important that faculty members include research-based information when instructing on management of patients receiving mechanical ventilation and suctioning practices. Staff members also stated that their practices are influenced by their hospital’s policies and procedures; therefore, it is important that advanced practice nurses and other resource personnel write the policies and base them on current evidence. Because most staff members do not routinely base their practice on journal articles they have read, those who write the policies must translate published research findings into clinical practice.

Institutions are encouraged to evaluate existing policies and procedures and to develop comprehensive policies and procedures for CSS and airway management practices. Both nursing and respiratory care departments should collaborate to write policies and procedures. Policies related to CSS and airway management must include steps for performing procedures, oral suctioning, protocols for oral care for intubated patients, and equipment management. Management of endotracheal tubes, including measurements of cuff pressure, suctioning above the cuff when repositioning the tube, and changing bite blocks or oral airways, must be addressed. A comprehensive strategy to communicate changes in policies and procedures to both nurses and respiratory therapists is important.

Collaborative practice teams are needed to address suctioning and airway management practices. Such teams can identify best practices and strategies for disseminating information and evaluating effectiveness of practice changes.

Comprehensive airway management protocols that reduce the compartmentalization of care are needed. Our findings indicate that nurses manage oral care, whereas respiratory therapists manage the endotracheal tube. This division of responsibilities can result in a lack of awareness of policies, different methods for performing airway management, failure to perform important activities (eg, oral suctioning) as often as needed, and the possibility that each discipline assumes that the other has completed a patient’s care. Incorporating comprehensive airway management activities into critical care flow sheets is another way to ensure that activities are done and documented.

Staff members should be reminded of the importance of wearing gloves for CSS and airway management procedures at all times. Although the CSS device is covered in a plastic sheath, gloves may help prevent transmission of bacteria to or from the patient. Concomitant oral care and suctioning should be encouraged if needed. Methods for reducing contamination of oral suction devices, including evaluation of disposable suction swabs and devices, must be evaluated.

More research is needed regarding oral hygiene, oral suctioning, suctioning equipment, and airway management as related to VAP rates. Potential research questions include the following:

Ongoing research is needed to identify the best practices for suctioning and airway management. Outcomes of research should be used to evaluate standard practices and strategies for reducing VAP in intubated patients.


    Conclusion
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 
Policies on suctioning and airway management practices vary widely and do not always reflect research-based practices. Routine care such as oral care and suctioning is often not addressed. Textbooks and polices do not reflect current evidence. Collaborative, research-based practice guidelines must be developed to ensure best practices for intubated patients.


{blacksquare} These data suggest that practice does not consistently reflect the most recent evidence, especially related to timing of changes of closed-system suctioning catheters, use of isotonic sodium chloride solution, management of endotracheal cuff pressures, and oral care frequency and procedures.

{blacksquare} Use of research findings and collaboration between nurses and respiratory therapists is essential for optimal and consistent airway management.

 


    ACKNOWLEDGMENTS
 
We thank Suzanne Burns, RN, RRT, MSN, ACNP, Patricia Carroll, RRT, RN, MS, and C. Lynne Ostrow, RN, EdD, for serving as content experts. Special thanks to the 27 site coordinators who worked diligently to ensure success of this study and achieved a 55% response rate from staff members in their units who participated in the study. Funding for this research was provided by a clinical practice grant from the American Association of Critical-Care Nurses, an unrestricted grant from Smith Industries, the Metropolitan Orlando chapter of American Association of Critical-Care Nurses, and the University of Central Florida School of Nursing.

To purchase reprints, contact The InnoVision Group, 101 Columbia, Aliso Viejo, CA 92656. Phone, (800) 809–2273 or (949) 362–2050 (ext 532); fax, (949) 362–2049; e-mail, reprints{at}aacn.org.

Commentary by Mary Jo Grap (see shaded boxes).


    REFERENCES
 Top
 Abstract
 Background and Significance
 Purposes
 Methods
 Sampling
 Instruments
 Procedures
 Results
 Discussion
 Implications
 Conclusion
 References
 

  1. Paul-Allen J, Ostrow CL. Survey of nursing practices with closed-system suctioning. Am J Crit Care. 2000;9:9–19.[Abstract]
  2. Sole ML, Poalillo FE, Byers JF, Ludy JE. Bacterial growth in secretions and on suctioning equipment of orally intubated patients: a pilot study. Am J Crit Care. 2001;11:141–149.
  3. Sole ML, Byers JF, Ludy JE, Ostrow CL. Suctioning techniques and airway management practices: pilot study and instrument evaluation. Am J Crit Care. 2002;11:363–368.[Free Full Text]
  4. Guidelines for prevention of nosocomial pneumonia. Centers for Disease Control and Prevention. MMWR Recomm Rep. 1997;46(RR-1):1–79.[Medline]
  5. AARC practice guideline: endotracheal suctioning of mechanically ventilated adults and children with artificial airways. Respir Care. 1993;38:500–504.[Medline]
  6. Henneman E, Ellstrom K, St. John R. Airway Management. Aliso Viejo, Calif: American Association of Critical-Care Nurses; 1998.
  7. Morehead RS, Pinto SJ. Ventilator-associated pneumonia. Arch Intern Med. 2000;160:1926–1936.[Abstract/Free Full Text]
  8. Chastre J, Fagon JY. Ventilator-associated pneumonia. Am J Respir Crit Care Med. 2002;165:867–903.[Abstract/Free Full Text]
  9. Fagon JY, Chastre J, Hance AJ, Montravers P, Novara A, Gibert C. Nosocomial pneumonia in ventilated patients: a cohort study evaluating attributable mortality and hospital stay. Am J Med. 1993;94:281–288.[Medline]
  10. Beck-Sague CM, Sinkowitz RL, Chinn RY, Vargo J, Kaler W, Jarvis WR. Risk factors for ventilator-associated pneumonia in surgical intensive care unit patients. Infect Control Hosp Epidemiol. 1996;17:374–376.[Medline]
  11. Craven DE, Steger KA. Ventilator-associated bacterial pneumonia: challenges in diagnosis, treatment, and prevention. New Horiz. 1998;6(2 suppl):S30–S45.[Medline]
  12. Kollef MH. The prevention of ventilator-associated pneumonia. N Engl J Med. 1999;340:627–634.[Free Full Text]
  13. Barie PS. Importance, morbidity, and mortality of pneumonia in the surgical intensive care unit. Am J Surg. 2000;179(2 suppl 1):2–7.[Medline]
  14. Byers JF, Sole ML. Analysis of factors related to the development of ventilator-associated pneumonia: use of existing databases. Am J Crit Care. 2000;9:344–349.[Abstract]
  15. Centers for Disease Control and Prevention. Semiannual Report: Aggregated Data From the National Nosocomial Infections Surveillance (NNIS) System. Atlanta, Ga: US Dept of Health and Human Services; December 2000.
  16. Harris JR, Joshi M, Morton PG, Soeken KL. Risk factors for nosocomial pneumonia in critically ill trauma patients. AACN Clin Issues. 2000;11:198–231.[Medline]
  17. Bercault N, Boulain T. Mortality rate attributable to ventilator-associated nosocomial pneumonia in an adult intensive care unit: a prospective case-control study. Crit Care Med. 2001;29:2303–2309.[Medline]
  18. Munro C, Grap M. Oral health status: effect on VAP. Paper presented at: 15th Anniversary Conference of the Southern Nursing Research Society, February 2001, Baltimore, Md.
  19. Hixson S, Sole ML, King T. Ventilator-associated pneumonia. AACN Clin Issues. 1998;9:76–90.[Medline]
  20. Kollef MH, Prentice D, Shapiro SD, et al. Mechanical ventilation with or without daily changes of in-line suction catheters. Am J Respir Crit Care Med. 1997;156(2 pt 1):466–472.[Abstract/Free Full Text]
  21. Adams DH, Hughes M, Elliott TS. Microbial colonization of closed-system suction catheters used in liver transplant patients. Intensive Crit Care Nurs. 1997;13:72–76.[Medline]
  22. Johnson KL, Kearney PA, Johnson SB, Niblett JB, MacMillan NL, McClain RE. Closed versus open endotracheal suctioning: costs and physiologic consequences. Crit Care Med. 1994;22:658–666.[Medline]
  23. Baker T, Taylor M, Wilson M, Rish J, Brazeal S. Evaluation of a closed-system endotracheal suction catheter [abstract]. Am J Infect Control. 1989;17:97.
  24. Conrad SA, George RB, Romero MD, Owens MW. Comparison of nosocomial pneumonia rates in closed and open tracheal suction systems [abstract]. Chest. 1989;96:184S.
  25. Deppe SA, Kelly JW, Thoi LL, et al. Incidence of colonization, nosocomial pneumonia, and mortality in critically ill patients using a Trach Care closed-systems versus an open-suction system: prospective, randomized study. Crit Care Med. 1990;18:1389–1393.[Medline]
  26. Combes P, Fauvage B, Oleyer C. Nosocomial pneumonia in mechanically ventilated patients, a prospective randomised evaluation of the Stericath closed suctioning system. Intensive Care Med. 2000;26:878–882.[Medline]
  27. Harshbarger S, Hoffman L, Zullo T, Pinsky M. Effects of a closed tracheal suction system on ventilatory and cardiovascular parameters. Am J Crit Care. 1992;1:57–61.[Abstract]
  28. Craig K, Benson M, Pierson D. Prevention of arterial oxygen desaturation during closed-airway endotracheal suction: effect of ventilator mode. Respir Care. 1984;29:1013–1018.
  29. Crimlisk JT, Paris R, McGonagle EG, Calcutt JA, Farber HW. The closed tracheal suction system: implications for critical care nursing. Dimens Crit Care Nurs. 1994;13:292–300.[Medline]
  30. Schwenker D, Ferrin M, Gift AG. A survey of endotracheal suctioning with instillation of normal saline. Am J Crit Care. 1998;7:255–260.[Abstract]
  31. Blackwood B. The practice and perception of intensive care staff using the closed suctioning system. J Adv Nurs. 1998;28:1020–1029.[Medline]
  32. Swartz K, Noonan DM, Edwards-Beckett J. A national survey of endotracheal suctioning techniques in the pediatric population. Heart Lung. 1996;25:52–60.[Medline]
  33. Ackerman MH. The effect of saline lavage prior to suctioning. Am J Crit Care. 1993;2:326–330.[Abstract]
  34. Ackerman MH, Mick DJ. Instillation of normal saline before suctioning in patients with pulmonary infections: a prospective randomized controlled trial. Am J Crit Care. 1998;7:261–266.[Abstract]
  35. Ackerman MH, Ecklund MM, Abu-Jumah M. A review of normal saline instillation: implications for practice. Dimens Crit Care Nurs. 1996;15:31–38.[Medline]
  36. Hagler DA, Traver GA. Endotracheal saline and suction catheters: sources of lower airway contamination. Am J Crit Care. 1994;3:444–447.[Abstract]
  37. Kinloch D. Instillation of normal saline during endotracheal suctioning: effects on mixed venous oxygen saturation. Am J Crit Care. 1999;8:231–240.[Abstract]
  38. Raymond SJ. Normal saline instillation before suctioning: helpful or harmful? A review of the literature. Am J Crit Care. 1995;4:267–271.[Abstract]
  39. Fink JB, Hunt GE. Clinical Practice in Respiratory Care. Philadelphia, Pa: JB Lippincott; 1999.
  40. Goll CA. Mechanical ventilation. In: Swearingen PL, Keen JH, eds. Manual of Critical Care Nursing: Nursing Interventions and Collaborative Management. St Louis, Mo: Mosby; 2001.
  41. Sole ML, Byers JF. Ventilatory assistance. In: Sole ML, Lamborn ML, Hartshorn J, eds. Introduction to Critical Care Nursing. 3rd ed. Philadelphia, Pa: WB Saunders Co; 2001.
  42. Deutsch JM. Endotracheal tube care. In: Lynn-McHale DJ, Carlson KK, eds. AACN Procedure Manual for Critical Care. 4th ed. Philadelphia, Pa: WB Saunders Co; 2001.
  43. Bergmans DC, Bonten MJ, Gaillard CA, et al. Prevention of ventilator-associated pneumonia by oral decontamination: a prospective, randomized, double-blind, placebo-controlled study. Am J Respir Crit Care Med. 2001;164:382–388.[Abstract/Free Full Text]
  44. Houston S, Hougland P, Anderson JJ, LaRocco M, Kennedy V, Gentry LO. Effectiveness of 0.12% chlorhexidine gluconate oral rinse in reducing prevalence of nosocomial pneumonia in patients undergoing heart surgery. Am J Crit Care. 2002;11:567–570.[Abstract/Free Full Text]
  45. Ajemian MS, Nirmul GB, Angerson MT, Zirlen DM, Kwasnik EM. Routine fiberoptic endoscopic evaluation of swallowing following prolonged intubation: implications for management. Arch Surg. 2001;136:434–437.[Abstract/Free Full Text]
  46. Redick EL. Closed-system, in-line endotracheal suctioning. Crit Care Nurse. August 1993;13:47–51.[Medline]
  47. Pilbeam SP. Mechanical Ventilation: Physiological and Clinical Applications. 3rd ed. St Louis, Mo: Mosby; 1998.
  48. Greenlee KK. Tracheal tube cuff care. In: Lynn-McHale DJ, Carlson KK, eds. AACN Procedure Manual for Critical Care. 4th ed. Philadelphia, Pa: WB Saunders Co; 2001.
  49. Crimlisk JT, Horn MH, Wilson DJ, Marino B. Artificial airways: a survey of cuff management practices. Heart Lung. 1996;25:225–235.[Medline]
  50. St John RE. Advances in airway management. Crit Care Nurs Clin North Am. 1999;11:7–17.[Medline]
  51. Sole ML, Combs SM, Willis J. Changes in endotracheal cuff pressures over time [abstract]. Crit Care Med. 2003;31(2 suppl):A144.
  52. Scanlan CL, Wilkins RL, Stoller JK. Egan’s Fundamentals of Respiratory Care. 7th ed. St Louis, Mo: Mosby; 1999.
  53. Benumof JL. Airway Management: Principles and Practice. St Louis, Mo: Mosby; 1996.
  54. Rello J, Sonora R, Jubert P, Artigas A, Rue M, Valles J. Pneumonia in intubated patients: role of respiratory airway care. Am J Respir Crit Care Med. 1996;154:111–115.[Abstract]
  55. Blackwood B, Webb CH. Closed tracheal suctioning systems and infection control in the intensive care unit. J Hosp Infect. 1998;39:315–321.[Medline]



This article has been cited by other articles:


Home page
Am J Crit CareHome page
L. L. Feider, P. Mitchell, and E. Bridges
Oral Care Practices for Orally Intubated Critically Ill Adults
Am. J. Crit. Care., March 1, 2010; 19(2): 175 - 183.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
R. Kjonegaard, W. Fields, and M. L. King
Current Practice in Airway Management: A Descriptive Evaluation
Am. J. Crit. Care., March 1, 2010; 19(2): 168 - 173.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. J. Grap
Not-so-Trivial Pursuit: Mechanical Ventilation Risk Reduction
Am. J. Crit. Care., July 1, 2009; 18(4): 299 - 309.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
M. L. Sole, D. A. Penoyer, X. Su, E. Jimenez, S. J. Kalita, E. Poalillo, J. F. Byers, M. Bennett, and J. E. Ludy
Assessment of Endotracheal Cuff Pressure by Continuous Monitoring: A Pilot Study
Am. J. Crit. Care., March 1, 2009; 18(2): 133 - 143.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
L. Rose and L. Redl
Survey of Cuff Management Practices in Intensive Care Units in Australia and New Zealand
Am. J. Crit. Care., September 1, 2008; 17(5): 428 - 435.
[Abstract] [Full Text] [PDF]


Home page
Crit Care NurseHome page
C. A. Rauen, M. Chulay, E. Bridges, K. M. Vollman, and R. Arbour
Seven Evidence-Based Practice Habits: Putting Some Sacred Cows Out to Pasture
Crit. Care Nurse, April 1, 2008; 28(2): 98 - 123.
[Full Text] [PDF]


Home page
Crit Care NurseHome page
M. A. Seckel
Ask the Experts
Crit. Care Nurse, February 1, 2008; 28(1): 65 - 66.
[Full Text] [PDF]


Home page
Am J Crit CareHome page
C. L. Cason, T. Tyner, S. Saunders, and L. Broome
Nurses' Implementation of Guidelines for Ventilator-Associated Pneumonia From the Centers for Disease Control and Prevention
Am. J. Crit. Care., January 1, 2007; 16(1): 28 - 37.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
C. J. Cutler and N. Davis
Improving Oral Care in Patients Receiving Mechanical Ventilation
Am. J. Crit. Care., September 1, 2005; 14(5): 389 - 394.
[Abstract] [Full Text] [PDF]


Home page
Crit Care NurseHome page
M. F. D. Pate and R. E. St. John
Placement of endotracheal and tracheostomy tubes
Crit. Care Nurse, June 1, 2004; 24(3): 13 - 14.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Respond to This Article
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Right arrow Take the CE Test
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sole, M. L.
Right arrow Articles by Brummel, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sole, M. L.
Right arrow Articles by Brummel, K.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS